MediBeacon® Transdermal GFR System receives device approval in China
- Transdermal GFR System (TGFR) is a first-in-kind product for point of care assessment of kidney function in patients with normal or impaired renal function.
The Clinical Kidney Journal in February published MediBeacon study results on measured GFR (mGFR) using relmapirazin versus estimated GFR (eGFR) for the purpose of classifying patient Chronic Kidney Disease (CKD) stages.- MediBeacon TGFR study results have been posted online in the February ahead of print section in the
Journal of the American Society of Nephrology (JASN).
In 2021, the NMPA granted the TGFR Innovative Medical Device Designation. Only 10% of applications are granted this designation. Benefits of this registration route including early product promotion are considerable.
In February, the
“The
In the February ahead of print section in the
In addition to his leadership role at
“Awareness of kidney disease is relatively low despite the fact that it is the 7th leading risk factor for mortality worldwide.4 MediBeacon is pleased to have the opportunity to aid in the assessment of kidney function in China,” said
The TGFR, which includes Lumitrace (relmapirazin), was approved on
About INNOVATE
INNOVATE Corp. is a portfolio of best-in-class assets in three key areas of the new economy – Infrastructure, Life Sciences and Spectrum. Dedicated to stakeholder capitalism, INNOVATE employs approximately 4,000 people across its subsidiaries. For more information, please visit: www.INNOVATECorp.com.
About
MediBeacon is a medical technology company specializing in the advancement of fluorescent tracer agents and their transdermal detection. MediBeacon’s use of proprietary fluorescent tracer agents coupled with transdermal detection technology focuses on providing vital and actionable measurement of organ function. MediBeacon owns over 55 granted
About Lumitrace® (relmapirazin) injection
Relmapirazin is a non-radioactive, non-iodinated pyrazine-based compound, which has been engineered to be inert, highly fluorescent, and have the clearance properties of a GFR tracer agent in the body. The unique photophysical characteristics of Lumitrace have been designed to enable the collection of fluorescence data via a photodetector sensor placed on the skin. Data collected by the sensor measures the change in the intensity of Lumitrace fluorescence over time and is converted into a transdermal GFR (tGFR) by proprietary algorithms. In a phase 2 investigational study mGFR deduced from Lumitrace matched that of mGFR deduced from iohexol over a range of GFR values. See the peer reviewed article published in the
About MediBeacon® Transdermal GFR System (TGFR)
The TGFR is comprised of the TGFR Sensor, TGFR Monitor, and Lumitrace® (relmapirazin), which together allow assessment of kidney function by measuring the clearance rate of the fluorescent agent as it leaves the body. The system records Lumitrace fluorescence intensity transdermally as a function of time via a sensor placed on the skin. The TGFR Sensor records 2.5 fluorescent readings per second and the TGFR Monitor will display the average session tGFR reading at the patient’s bedside or in the outpatient setting.
Forward-Looking Statements
Certain statements in this press release may constitute “forward-looking statements” within the meaning of the federal securities laws. Forward-looking statements generally relate to future events. You are cautioned that such statements are not guarantees of future performance and that INNOVATE’s actual results may differ materially from those set forth in the forward-looking statements. All of these forward-looking statements are subject to risks and uncertainties that may change at any time. Factors that could cause INNOVATE’s actual expectations to differ materially from these forward-looking statements include INNOVATE’s ability to continue to comply with applicable listing standards of the NYSE and the other factors under the heading “Risk Factors” set forth in INNOVATE’s Annual Report on Form 10-K, as supplemented by INNOVATE’s quarterly reports on Form 10-
Investor Contact:
ir@innovatecorp.com
(212) 235-2691
IMPORTANT SAFETY INFORMATION FOR TGFR (
Indication for Use:
The MediBeacon® Transdermal GFR System (TGFR) is intended to assess the Glomerular Filtration Rate (GFR) in adult patients with impaired or normal renal function by noninvasively monitoring fluorescent light emission from an exogenous tracer agent over time. This device has been validated in patients with stable renal function.
The MediBeacon® TGFR is not approved for use in patients with GFR <15ml/min/1.73m2, GFR >120ml/min/1.73m2, patients on dialysis or anuric patients. The use of this device in patients with dynamic and rapidly changing renal function has not been validated. This device is not intended to diagnose acute kidney injury (AKI).
The MediBeacon® TGFR Sensor and exogenous tracer agent, Lumitrace® injection, are single use and are only used with the MediBeacon® TGFR.
The MediBeacon® TGFR Sensor is a single use device intended to attach to the patient's skin and excite fluorescence in Lumitrace® injection, the tracer agent, and measure the returning light intensity. The data is sent to the MediBeacon® TGFR Monitor.
Lumitrace® is an injectable exogenous fluorescent tracer indicated for use with the MediBeacon® Transdermal GFR System (TGFR) for Glomerular Filtration Rate assessment.
Contraindications:
There are no known contraindications.
Warnings and Precautions:
- See ifu.medibeacon.com for full instructions, warnings, and cautions.
- In clinical studies no serious or severe adverse events have been observed.
- Lumitrace® injection has light absorbance at 266nm and 435nm, and broad fluorescent emission at ~560nm when excited at ~440nm. Any drug activated at these wavelengths should not be used in conjunction with Lumitrace.
- Lumitrace injection may interfere with clinical laboratory tests. DO NOT ADMINISTER if the patient is expected to need clinical laboratory testing while Lumitrace is present in their system (up to 72 hours for renally-impaired patients). The presence of Lumitrace decreased B-Type Natriuretic Peptide (BNP) results by around 20% in limited testing.
- Bolus infusions may impact the GFR assessment temporarily while the vasculature-tissue equilibrium is re-established.
- During a TGFR session, the patient should be as still as possible, especially during the “Establishing Baseline” stage. The current system is designed to compensate for light activity such as reading or eating after the Baseline stage.
1 CKD stage misclassification between estimated GFR and measured GFR in a clinical study of chronic kidney patients,
2 Glomerular Filtration Rate Measurement Utilizing Transdermal Detection Methodology,
3 https://www.asn-online.org/publications/
4 Chronic kidney disease and the global public health agenda: an international consensus, Nature Reviews Nephrology, 20, 473-485 (2024), doi.org/10.1038/s41581-024-00820-6
5 Clinical validation of the novel fluorescent glomerular filtration rate tracer agent relmapirazin (MB-102),
Source: INNOVATE Corp.